OIL IMMERSED TRANSFORMERS

The three-phase oil-immersed distribution transformers feature different voltages and power ratings up to 6,000 KVA (10 MVA available on request). These highly efficient and reliable transformers provide the required electrical power supply without breakage or interruption.

Pad Mounted Transformer

Standard Technical Specifications:

StandardIEC60076 & SEC
Rated frequency60 HZ
Connection and vector groupDyn11*
Ambient temperatureerature55 °C
Max temperature riseTop oil45 °C
Average winding50 °C
Type of coolingONAN
HV tappingOff-circuit tap changer 5 positions± 2×2.5 * %

Note: Custom specifications and requirements can be designed and manufactured upon request.

Rated PowerHVLVNO Load LossLoad LossZ%WidthDepthHeight
KVAVVWW%mmmmmm
30013.80.452032004170014001600
50013.80.472047005170014001600
100013.80.4110090006190016001900
150013.80.41700140006192017002000
300330.452032004170014001600
500330.475047005170014001600
1000330.4110090006190016001900
1500330.41700140006192017002000

Note: Custom specifications and requirements can be designed and manufactured upon request.

Pole Mounted Transformer

Standard Technical Specifications:

StandardIEC60076 & SEC
Rated frequency60 HZ
Connection and vector groupDyn11*
Ambient temperature55 °C
Max temperature riseTop oil45 °C
Average winding50 °C
Type of coolingONAN
HV tappingOff-circuit tap changer 5 positions± 2×2.5 * %

Note: other specifications and requirements are also designed and manufactured upon request.

Rated PowerHVLVNO Load LossLoad LossZ%WidthDepthHeight
KVAVVWW%mmmmmm
10013.80.42501500413509001450
20013.80.438022004145011001700
30013.80.452032004145011001700
100330.42501500413509001450
200330.438022004145011001700
300330.452032004145011001700

Note: Custom specifications and requirements can be designed and manufactured upon request.

Unit Substations Transformer

Standard Technical Specifications:

StandardIEC60076 & SEC
Rated frequency60 HZ
Connection and vector groupDyn11*
Ambient temperature55 °C
Max temperature riseTop oil45 °C
Average winding50 °C
Type of coolingONAN
HV tappingOff-circuit tap changer 5 positions± 2×2.5 * %

Note: Custom specifications and requirements can be designed and manufactured upon request.

Rated PowerHVLVNO Load LossLoad LossZ%
KVAVVWW%
30013.80.452032004
50013.80.475047005
100013.80.4110090006
150013.80.41700140006

Note: Custom specifications and requirements can be designed and manufactured upon request.

Power Transformer

Standard Technical Specifications:

StandardIEC60076
Rated Powerup to 6000 KVA
Rated frequency60 HZ
Maximum system voltageup to 36 KV
Secondary voltageFrom 4.16 KV
Connection and vector groupDyn11*
Ambient temperature55 °C
Max temperature riseTop oil45 °C
Average winding50 °C
Type of coolingONAN
HV tappingOff-circuit tap changer 5 positions± 2×2.5 * %

Note: Custom specifications and requirements can be designed and manufactured upon request.

Back to top button